hβ
Point height3.6052 mmThickness plus point height23.6052 mm
h = (D / 2) / tan(β / 2); L = e + h

Interpretation and limits

Geometry of an ideal symmetrical conical point. β is the included angle, not its half-angle. The sum excludes exit clearance and does not define a safe programmed depth. Step, flat-bottom and special drills require their actual geometry and the machine procedure.

Example: D = 12 mm, β = 90° and thickness 20 mm give h = 6 mm and geometric total 26 mm.