← Back

Process · 9 min

Coolant: concentration, flow and direction

Control concentration, flow, direction and maintenance of cutting fluid.

Control concentration, flow, direction and maintenance of cutting fluid.

Visible fluid flow alone does not confirm adequate cooling or lubrication. For water-miscible fluids, concentration, delivery and cleanliness must be controlled using the product instructions.

Measure using the correct factor

Clean and zero the refractometer as specified. Use a representative sample and the product-specific factor; do not assume a Brix reading is the final concentration. Arithmetic example only: reading 4 multiplied by factor 1.5 gives 6%. This is not a recommended target for every fluid or operation.

Do not adjust by appearance

Use the specified operating range and mixing procedure. Record date, reading, factor, calculated concentration and any addition. A blurred reading or contaminated sample requires investigation; adding concentrate until the mixture looks right is not a measurement. Follow the supplier procedure for correction and top-up.

Check delivery at the cut

Confirm nozzle position, flow, filtration and any specified pressure. Check for restrictions and intermittent supply with the machine in the required safe state. Pressure at the pump alone does not demonstrate delivery at the cutting edge. Keep within machine and tool limits; do not improvise higher pressure.

Maintain and handle safely

Monitor level, contamination, filtration and the additional checks specified for the product, including pH where applicable. Follow the safety data sheet, protective measures and approved waste procedure. Do not add biocides or mix different products without the prescribed authorization and supplier guidance.

Blaser Swisslube · Measuring coolant concentration